CryoCube® F570 series  Eppendorf
CryoCube® F570 series
Eppendorf


The Eppendorf CryoCube F570 series of ULT freezers (also known as ultra-low temperature freezer / -80 °C freezer) is based on a strong compressor for fast recovery to -80 °C after opening. As this class of freezer is often used as real-lab freezer, multiple openings per day are normal - a dynamic and strong cooling system is mandatory for fast recovery to -80 °C after every opening. Provide your valuable samples a safe and cold location. The freezer minimizes operating costs while providing superior protection for your critical samples. A combined insulation based on vacuum insulation panels and polyurethane foam enables extremely low energy consumption during long-term storage ("h" versions). Benefit from sustainable cold storage combined with safe sample storage.
Technical Data:
Cooling liquid:R290 / R170
Cooling type:air cooling (570n und 570h)
water cooling (570hw)
Power supply:230 V
Capacity:570 l
Number of internal doors:5
Number of compartments:5
Max. racks per freezer:25
Footprint (WxD):110.3 x 89.9 cm
Temperatur range:-50 °C to -86 °C
TypeVersionOrder No.PU Manuf. Prod. No. 
air-cooledpolyurethane insulation52073351-F571300031 
air-cooledpolyurethane insulation and vacuum insulation panels52073431-F571340031 
water-cooledpolyurethane insulation and vacuum insulation panels52073441-F571340131 
air-cooled, with Chart Recorderpolyurethane insulation52073371-F571301031 
air-cooled, with Chart Recorderpolyurethane insulation and vacuum insulation panels52073451-F571341031 
water-cooled, with Chart Recorderpolyurethane insulation and vacuum insulation panels52073461-F571341131 
air-cooled, CO2 Back-up Systempolyurethane insulation52073381-F571302031 
air-cooled, CO2 Back-up Systempolyurethane insulation and vacuum insulation panels52073471-F571342031 
water-cooled, CO2 Back-up Systempolyurethane insulation and vacuum insulation panels52073481-F571342131 
air-cooled, LN2 Back-up Systempolyurethane insulation52073391-F571303031 
air-cooled, LN2 Back-up Systempolyurethane insulation and vacuum insulation panels52073501-F571343031 
water-cooled, LN2 Back-up Systempolyurethane insulation and vacuum insulation panels52073511-F571343131 
air-cooled, with Chart Recorder, CO2 Back-up Systempolyurethane insulation52073411-F571304031 
air-cooled, with Chart Recorder, CO2 Back-up Systempolyurethane insulation and vacuum insulation panels52073521-F571344031 
water-cooled, with Chart Recorder, CO2 Back-up Systempolyurethane insulation and vacuum insulation panels52073531-F571344131 
air-cooled, with Chart Recorder, LN2 Back-up Systempolyurethane insulation52073421-F571305031 
air-cooled, with Chart Recorder, LN2 Back-up Systempolyurethane insulation and vacuum insulation panels52073541-F571345031 
water-cooled, with Chart Recorder, LN2 Back-up Systempolyurethane insulation and vacuum insulation panels52073551-F571345131