Z.š. | Opis | |
---|
1 | Clamp for spray chamber, to clamp spray chamber/connector/torch, 2/pk | |
2 | Connector, perfluoroalkoxy (PFA), for MicroFlow nebulizer | |
3 | Drain Tank (with PVC connector, 1 liter) | |
4 | End cap for spray chamber used with ICP-MS | |
5 | End cap, perfluoroalkoxy (PFA), for MicroFlow nebulizer, no O-ring required | |
6 | G1820-65138: Nebulizer, concentric, quartz, Agilent 7500/7700 and 8800 series I… | |
7 | G1820-65199: O-ring for Babington nebulizer, Viton, Agilent 7500 ICP-MS, to cre… | |
8 | G1820-65491: O-ring kit for concentric nebulizer, Agilent 7500/7700 and 8800 se… | |
9 | G1820-65520: O-ring for concentric nebulizer when used with organic solvents, A… | |
10 | G3138-65143: Y connector for pump tubing, 2.5 mm id, Agilent ICP-MS integrated … | |
11 | G3139-65003: Spray chamber, perfluoroalkoxy (PFA), MicroFlow nebulizer, standar… | |
12 | G3139-65100: Nebulizer, MicroFlow, perfluoroalkoxy (PFA), 200 uL/min, Agilent 7… | |
13 | G3139-65102: Nebulizer, MicroFlow, perfluoroalkoxy (PFA), with Agilent integrat… | |
14 | G3139-65106: Nebulizer, MicroFlow, perfluoroalkoxy (PFA), Agilent 7500/7700 and… | |
15 | G3139-65108: Nebulizer, MicroFlow, perfluoroalkoxy (PFA) with Agilent integrate… | |
16 | G3161-80000: Nebulizer, MiraMist, PTFE, Agilent 7500/7700 and 8800 series ICP-M… | |
17 | G3161-80001: Nebulizer, MiraMist, PEEK, Agilent 7500/7700 and 8800 series ICP-M… | |
18 | G3266-65003: Nebulizer, MicroMist, borosilicate glass, standard with Agilent 77… | |
19 | G3266-80004: Nebulizer, MicroMist, borosilicate glass, UniFit sample connector,… | |
20 | G3266-80010: Sample inlet fitting, EzyFit, for MicroMist concentric nebulizer f… | |
21 | G3266-80011: Sample inlet fitting, EzyFit, fitting for MicroMist concentric neb… | |
22 | G3266-80012: Sample connector, UniFit, 0.5 mm id, with 0.5 mm id x 700 mm capil… | |
23 | G3266-80013: Sample connector, UniFit, 0.25 mm id, with 0.25 mm id x 700 mm cap… | |
24 | G3266-80015: Connector, carrier gas inlet, EzyLok, for MicroMist nebulizer used… | |
25 | G3266-80020: Nebulizer cleaner, for glass concentric nebulizers, allows capilla… | |
26 | G3280-67115: O-ring A, perfluoroalkoxy (PFA), 1.07 mm od, for concentric nebuli… | |
27 | G3280-67116: O-ring B, perfluoroalkoxy (PFA), 3.8 mm od, for concentric nebuliz… | |
28 | G3280-80008: Spray chamber, double-pass, quartz, standard for Agilent 7700/8800… | |
29 | G3280-80602: Nebulizer, total consumption, for capillary LC, suits capillary LC… | |
30 | G3280-80603: Spray chamber, single-pass, for capillary LC, suits capillary LC i… | |
31 | G3285-80020: End cap for inert kit, perfluoroalkoxy (PFA), with makeup gas port… | |
32 | G3285-80021: Spray chamber for inert kit, perfluoroalkoxy (PFA), suits inert sa… | |
33 | G3285-80022: Tube, drain, perfluoroalkoxy (PFA), for inert kit, suits inert sam… | |
34 | G4912-68000: Inert sample introduction kit, 2.5 mm id sapphire injector tube an… | |
35 | G4912-68001: Inert sample introduction kit, 2.5 mm id platinum injector tube an… | |
36 | G4912-68002: Inert sample introduction kit, 1.5 mm id sapphire injector tube an… | |
37 | G4912-68003: Inert sample introduction kit, 1.5 mm id platinum injector tube an… | |
38 | G4912-80014: Tube, drain, perfluoroalkoxy (PFA), for inert kit, suits perfluoro… | |
39 | G8400-60327: Clamp, torch ball joint connector, secures ball joint connector be… | |
40 | Nebulizer, concentric, perfluoroalkoxy (PFA), 200 uL/min, with probe | |
41 | PFA Concentric Nebulizer (200uL/min.) | |
42 | PFA Concentric Nebulizer (50 uL/min) | |
43 | PFA Concentric Nebulizer (50 uL/min, with probe) | |
44 | Spray chamber (quartz) for UHMI, 7900 ICP-MS, 1/pk | |
45 | Tank, drain, polyethylene, 4 L | |